Maxtec Sensors Offer:
- A wide variety of Oxygen Sensors for respiratory & anesthesia.
- Your choice of OEM & alternative brands.
- Extended warranties & competitive pricing.
Call 1-800-654-9845 for Maxtec Cross Referencing Details or for additional information on Maxtec
Sensors.
|
|
Maxtec Products Supplied at Alpha Source
|
|
Maxtec Oxygen Sensors Stock
Number:
R113P90 Warranty: 12 Months
Replacement For: Analytical Industries [PSR-11-915], GE (Datex-Ohmeda) [0237-2034-700 Excel Modulus, 4700 Oxicap, 5250 RGM, 5120/5124 Monitor, 7800], HP [15201A], Hudson RCI [See Teleflex Medical], Mercury Medical [10-103-07], Pacifitech [PT-10], Teledyne [R15/#C-41131], Teleflex Medical (Hudson RCI) [5556], VTI [101272, 100352]
|
|
Stock
Number:
R107P20 Warranty: 18 Months
Replacement For: Analytical Industries [PSR-11-915-1], Drager [Narkomed Series, Fabius Series, Tiro, 6850645, 6803290], HP [15201A], Invivo [Magnitude], Mercury Medical [10-103-12], Pacifitech [PT-24], Teledyne, VTI [101372]
|
|
Stock
Number:
R109P11 Warranty: 12 Months
Replacement For: City Technology [MOX-3], Paragon [Platinum SC430], Penlon [Prima SP2]
|
|
Stock
Number:
R109P09 Warranty: 12 Months Replacement For: City Technology [MOX-4], EnviteC [OOM-105], International Technologies [M-07], Teledyne [AX/MX300 Series, R17MED/#C-43690
|
|
Stock
Number:
R107P22 Warranty: 18 Months
Replacement For: Analytical Industries [PSR-11-915-3], GE (Datex-Ohmeda) [0237-2034-700 Excel Modulus, 4700 Oxicap, 5250 (ext. only0, 5120/5125], Mercury Medical [10-103-13], Teledyne [R32MED/#B-73463], VTI [101272]
|
|
Stock
Number:
R114P80 Warranty: 14 Months
Replacement For: Airshields [see Hillrom], Analytical Industries [PSR-11-55], Hillrom (Airshields) [6736140], Hudson RCI [see Teleflex], Mercury Medical [10-103-03], Pacifitech [PT-05], Teledyne [R13, #B-39636], Teleflex Medical [Hudson RCI) [5500, V-05, 5590, 5577, 5584, 5595, 6477]
|
|
Stock
Number:
R112P10 Warranty: 12 Months
Replacement For: Analytical Industries [PSR-11-915-4], City Technology y[MOX-7], EnviteC [OOM-110], GE (Datex-Ohmeda) [6050-0004-110, Modulus SE, 7900 Series, Aisys, Aestiva Series, SmartVent S-5, Aespire], International Technologies [M-10], Mercury Medical [10-103-10], Pacifitech [PT-20A], Teledyne [P30MED/#B-72939]
|
|
Stock
Number:
R113P10 Warranty: 12 Months
Replacement For: Airshields [see Hillrom], City Technology [MOX-16], Drager [Narkomed, Fabius Series, Babylog, Evita Family, 6850645, 6803290, Cato
| 8000, EnviteC [OOM-201], Hillrom (Airshields) [PSR-11-915-2], Hudson RCI [See Teleflex Medical], International Technologies [M-02], Invivo [Magnitude, Mercury Medical [10-103-07], Pacifitech [PT-14A], Teledyne [R23, #C-61139], Teleflex Medical (Hudson RCI) [5557, V-14, VTI [101372, 100352]
|
|
Stock
Number:
R113P06 Warranty: 12 Months Replacement For: Drager Incubators [18000 high temperature applications]
|
|
Stock
Number:
R109P45 Warranty: 12 Months
Replacement For: Analytical Industries [PSR-11-917-M], City Technology [MOX-9], Datascope [Multinex Analyzer, 0600-00-0002 (use Max-12F)], EnviteC [OOM-202], Hamilton [396008, 396009, Galileo, Raphael, Arabelle, Aladdin, 51254], Hudson RCI [See Teleflex], IMT [PF300], International Technologies [M-04], Mercury Medical [10-103-06], MSA [472062, 470644], Pacifitech [PT-12A], Siemens [9004979-E347E], Spacelabs [90513, Capnograph], Teledyne [R24MED, #B-62321], Teleflex Medical (Hudson RCI) [5556, V-12], VTI [103100]
|
|
Stock
Number:
R109P48 Warranty: 14 Months
Replacement For: Hillrom (Airshields) [Isolette Incubator], Viasys [Avea Ventilator, Sipap]
|
|
Stock
Number:
R115P10 Warranty: 14 Months
Replacement For: Airshields [see Hillrom], Analytical Industries [PSR-11-917-J], BioMed Devices [10006 Sensor, M-10, M-2 Monitors, Sensor #4433, Monochrome Crossvent (Use Max-13c)], City Technologies [MOX-2], Covidien (Puritan-Bennett) [4-020933-00, 7820 Monitor, 7200 Vent], Datascope [Anestar S], EnviteC [OOM-102-1], Hillrom (Airshields) [6735142],
Hudson RCI [see Teleflex], Invivo [9445 Sensor], Mercury Medical
[10-103-05], MSA [40931, MiniOX I, II, III, 3000], Pacifitech [PT-11A],
Phillips (Respironics) [Criterion Vent, Espirit Vent, Lifecare
(#PLV-102), 37-079 Sensor], Precision Medical [PM5900, #504877],
Puritan-Bennett [see Covidien], Teledyne [R17MED, #C-43690 (see Max-7
for AX/MX300 replacement), Teleflex Medical [5567, V-11], Viasys [66030
Sensor, 6400 Vent, 8400 Vent, VIP Vent]
|
|
Stock
Number:
R125P07 Warranty: 24 Months
Replacement For: Airshields [see Hillrom], Analytical Industries [PSR-11-917-J], BioMed Devices [10006 Sensor, M-10, M-2 MOnitors, Sensor #4433, Monochrome Crossvent (use Max-13c)], City Technologies [MOX-2], Covidien (Puritan-Bennett) [4-020933-00, 7820 Monitor, 7200 Vent, Datascope [Anestar S], EnviteC [OOM-102-1],
Hillrom (Airshields) [6735142], Hudson RCI [see Teleflex], Invivo [9445
Sensors], Mercury Medical [10-103-05], MSA [40931, MiniOX I, II, III,
3000], Pacifitech [PT-11A], Phillips (Respironics) [Criterion Vent,
Espirit Vent, Lifecare (#PLV-102), 37-079 Sensor], Precision Medical
[PM5900, #504877], Puritan-Bennett [see Covidien], Teledyne [R17MED,
#C-43690 (see Max-7 for AX/MX300 replacement), Teleflex Medical [5567,
V-11], Viasys [66030 Sensor, 6400 Vent, 8400 Vent, VIP Vent], VTI
[100580]
|
|
Stock
Number:
R116P80 Warranty: 14 Months Replacement For: Devilbiss
[02ANA-101 Sensor], Mercury Medical [10-103-13], MSA [806572, MiniOx
IA], Pacifitech [PT-26]
|
|
Stock
Number:
R114P70
Warranty: 16 Months
Replacement For: Covidien (Puritan-Bennett) [4-072214-00, 840, 740, 760 & PB2000 Tester Vents]
|
|
Stock
Number:
R114P73 Warranty: 12 Months
Replacement For: Versamed [Versamed Vent] * Note: Oxygen cell
characterized by a particularly long life and extended temperature range (60C)
|
|
Stock
Number:
R116P10 Warranty: 12 Months
Replacement For: Analytical Industries [PSR-11-77], Hudson RCI [see Teleflex Medical], Mercury medical [10-103-02], Pacifitech [PT-03], Penlon [MTS], Teledyne [T-7],
Teleflex Medical [5558. V-03]
|
|
Stock
Number:
R116P40 Warranty: 12 Months
Replacement For: Analytical Industries [PSR-11-33-1], Hudson RCI [see Teleflex Medical], Mercury Medical [10-103-01], Pacifitech
[PT-02], Teledyne [C1R, #B-39022], Teleflex Medical [5569, V-02, 5525,
5528, 5529, 5550, 5552]
|
|
Stock
Number:
R116P60 Warranty: 12 Months
Replacement For: Analytical INdustries [PSR-11-33-1], Hamilton [HM-01, Veolar, Amadeus, Arabella], Hudson RCI [See Teleflex Medical], Mercury Medical [10-103-00], Pacifitech [PT-01], Teledyne [C1R, #A-37016], Teleflex Medical [5568 C1, C-01]
|
|
Stock
Number:
R116P06 Warranty: 12 Months
Replacement For: City Technologies [MOX-1], Criticare [Poet IQ 8500, IQ2 8500Q, CAT644 Sensor], EnviteC [OOM-102], Teledyne [R22, #C-44611]
|
|
Stock
Number:
R109P07 Warranty: 12 Months
Replacement For: GE (Datex-Ohmeda) [Giraffe]
|
|
Stock
Number:
R112P16 Warranty: 12 Months
Replacement For: Teleflex Medical (Hudson RCI) [5800 Monitor, 5801 Analyzer, 5803 Sensor]
|
|
Stock
Number:
R125P01-002 Warranty: 24 Months
Replacement For: Maxtec [OM-25A], Mercury Medical [10-103-11], Pacifitech [PT-250], Teledyne [R29]
|
|
Stock
Number:
R125P03-002 Warranty: 12 Months
Replacement For: Maxtec [MaxO2+AE, OM-25AE, OM-25ME, MaxBlend, MaxVenturi], Analytical Industries [PSR-11-917-J1], CareFusion (Cardinal, Viasys) [Sentry Blender], Fluke [VT Mobile], mercury Medical [10-103-08], Newport Medical [e360 & e500 Vents], Pacifitech [PT-25A], Teledyne [R29MED/#C-70592], Viasys [Sentry Blender, 66045]
|
|
Stock
Number:
R115P85 Warranty: 12 Months
Replacement For: Maxtec [MaxO2+AE, OM-25AE, OM-25ME, MaxBlend, MaxVenturi]
|
|
Stock
Number:
R125P02-011 Warranty: 24 Months
Replacement For: Maxtec [MaxO2+A]
|
|
Stock
Number:
R100P51-002 Warranty: 24 Months
|
|
Stock
Number:
R109P13 Warranty: 12 Months
|
|
Stock
Number:
R100P51-002 Warranty: 24 Months
Replacement For:Figaro [KE-25]
|
|
Stock
Number:
R109P15 Warranty: 12 Months
Replacement For:Stephan [Stephanie Infant Ventilator]
|
|
Stock
Number:
R109P53 Warranty:14 Months
Replacement For:Viasys [Avea Ventilator, Infant SiPaP]
|
|
Stock
Number:
R115P01 Warranty:14 Months
Replacement For:BioMed Devices [4433]
|
|
Stock
Number:
R115P85 Warranty: 12 Months
Replacement For:Maxtec [MaxO2+AE, OM-25AE, OM-25ME, MaxBlend, MaxVenturi]
|
|
Stock
Number:
R116P06 Warranty: 12 Months
Replacement For:City Technology [MOX-1],EnviteC [OOM-102],Teledyne [R22 #C-44611],Teleflex (Hudson) [5566].
|
|
Stock
Number:
R116P11 Warranty: 12 Months
Replacement For:Teleflex (Hudson) [5811]
|
|
Stock
Number:
R116P13 Warranty: 12 Months
Replacement For:Teleflex (Hudson) [5804]
|
|