- Maxtec Quality
- Send in 12 Oxygen Sensors, Get 1 Free!
Maxtec Quality
All Maxtec products meet the FDA's 510K requirements and the
EU's CE qualifications to ensure each and every product's superior quality.
With Maxtec Oxygen Sensors experience excellent warranties, stable
readings, and longer life.
Send in 12 Oxygen Sensors, Get 1 Free!
Alpha Source and Maxtec are pleased to announce the Frequent Buyer Program. Oxygen sensors, similar to batteries,
generally contain small amounts of lead. While taking care of our loyal
customers, we can also do our part in taking care of the environment.
Find out how you can Get Your Free Sensor.
Maxtec Sensors Offer:
- A wide variety of Oxygen Sensors for respiratory & anesthesia.
- Your choice of OEM & alternative brands.
- Extended warranties & competitive pricing.
Call 1-800-654-9845 for Maxtec Cross Referencing Details or for additional information on Maxtec
Sensors.
|
|
Maxtec Products Supplied at Alpha Source
|
Maxtec Oxygen Sensors Stock
Number:
ASR113P90 Warranty: 12 Months
Replacement For: Analytical Industries [PSR-11-915], GE (Datex-Ohmeda) [0237-2034-700 Excel Modulus, 4700 Oxicap, 5250 RGM, 5120/5124 Monitor, 7800], HP [15201A], Hudson RCI [See Teleflex Medical], Mercury Medical [10-103-07], Pacifitech [PT-10], Teledyne [R15/#C-41131], Teleflex Medical (Hudson RCI) [5556], VTI [101272, 100352]
|
|
Stock
Number:
ASR107P20 Warranty: 18 Months
Replacement For: Analytical Industries [PSR-11-915-1], Drager [Narkomed Series, Fabius Series, Tiro, 6850645, 6803290], HP [15201A], Invivo [Magnitude], Mercury Medical [10-103-12], Pacifitech [PT-24], Teledyne, VTI [101372]
|
|
Stock
Number:
ASR109P11 Warranty: 12 Months
Replacement For: City Technology [MOX-3], Paragon [Platinum SC430], Penlon [Prima SP2]
|
|
Stock
Number:
ASR109P09 Warranty: 12 Months Replacement For: City Technology [MOX-4], EnviteC [OOM-105], International Technologies [M-07], Teledyne [AX/MX300 Series, R17MED/#C-43690
|
|
Stock
Number:
ASR107P22 Warranty: 18 Months
Replacement For: Analytical Industries [PSR-11-915-3], GE (Datex-Ohmeda) [0237-2034-700 Excel Modulus, 4700 Oxicap, 5250 (ext. only0, 5120/5125], Mercury Medical [10-103-13], Teledyne [R32MED/#B-73463], VTI [101272]
|
|
Stock
Number:
ASR114P80 Warranty: 14 Months
Replacement For: Airshields [see Hillrom], Analytical Industries [PSR-11-55], Hillrom (Airshields) [6736140], Hudson RCI [see Teleflex], Mercury Medical [10-103-03], Pacifitech [PT-05], Teledyne [R13, #B-39636], Teleflex Medical [Hudson RCI) [5500, V-05, 5590, 5577, 5584, 5595, 6477]
|
|
Stock
Number:
ASR112P10 Warranty: 12 Months
Replacement For: Analytical Industries [PSR-11-915-4], City Technology y[MOX-7], EnviteC [OOM-110], GE (Datex-Ohmeda) [6050-0004-110, Modulus SE, 7900 Series, Aisys, Aestiva Series, SmartVent S-5, Aespire], International Technologies [M-10], Mercury Medical [10-103-10], Pacifitech [PT-20A], Teledyne [P30MED/#B-72939]
|
|
Stock
Number:
ASR113P10 Warranty: 12 Months
Replacement For: Airshields [see Hillrom], City Technology [MOX-16], Drager [Narkomed, Fabius Series, Babylog, Evita Family, 6850645, 6803290, Cato
| 8000, EnviteC [OOM-201], Hillrom (Airshields) [PSR-11-915-2], Hudson RCI [See Teleflex Medical], International Technologies [M-02], Invivo [Magnitude, Mercury Medical [10-103-07], Pacifitech [PT-14A], Teledyne [R23, #C-61139], Teleflex Medical (Hudson RCI) [5557, V-14, VTI [101372, 100352]
|
|
Stock
Number:
ASR113P06 Warranty: 12 Months Replacement For: Drager Incubators [18000 high temperature applications]
|
|
Stock
Number:
ASR109P45 Warranty: 12 Months
Replacement For: Analytical Industries [PSR-11-917-M], City Technology [MOX-9], Datascope [Multinex Analyzer, 0600-00-0002 (use Max-12F)], EnviteC [OOM-202], Hamilton [396008, 396009, Galileo, Raphael, Arabelle, Aladdin, 51254], Hudson RCI [See Teleflex], IMT [PF300], International Technologies [M-04], Mercury Medical [10-103-06], MSA [472062, 470644], Pacifitech [PT-12A], Siemens [9004979-E347E], Spacelabs [90513, Capnograph], Teledyne [R24MED, #B-62321], Teleflex Medical (Hudson RCI) [5556, V-12], VTI [103100]
|
|
Stock
Number:
ASR109P48 Warranty: 14 Months
Replacement For: Hillrom (Airshields) [Isolette Incubator], Viasys [Avea Ventilator, Sipap]
|
|
Stock
Number:
ASR115P10 Warranty: 14 Months
Replacement For: Airshields [see Hillrom], Analytical Industries [PSR-11-917-J], BioMed Devices [10006 Sensor, M-10, M-2 Monitors, Sensor #4433, Monochrome Crossvent (Use Max-13c)], City Technologies [MOX-2], Covidien (Puritan-Bennett) [4-020933-00, 7820 Monitor, 7200 Vent], Datascope [Anestar S], EnviteC [OOM-102-1], Hillrom (Airshields) [6735142],
Hudson RCI [see Teleflex], Invivo [9445 Sensor], Mercury Medical
[10-103-05], MSA [40931, MiniOX I, II, III, 3000], Pacifitech [PT-11A],
Phillips (Respironics) [Criterion Vent, Espirit Vent, Lifecare
(#PLV-102), 37-079 Sensor], Precision Medical [PM5900, #504877],
Puritan-Bennett [see Covidien], Teledyne [R17MED, #C-43690 (see Max-7
for AX/MX300 replacement), Teleflex Medical [5567, V-11], Viasys [66030
Sensor, 6400 Vent, 8400 Vent, VIP Vent]
|
|
Stock
Number:
ASR125P07 Warranty: 24 Months
Replacement For: Airshields [see Hillrom], Analytical Industries [PSR-11-917-J], BioMed Devices [10006 Sensor, M-10, M-2 MOnitors, Sensor #4433, Monochrome Crossvent (use Max-13c)], City Technologies [MOX-2], Covidien (Puritan-Bennett) [4-020933-00, 7820 Monitor, 7200 Vent, Datascope [Anestar S], EnviteC [OOM-102-1],
Hillrom (Airshields) [6735142], Hudson RCI [see Teleflex], Invivo [9445
Sensors], Mercury Medical [10-103-05], MSA [40931, MiniOX I, II, III,
3000], Pacifitech [PT-11A], Phillips (Respironics) [Criterion Vent,
Espirit Vent, Lifecare (#PLV-102), 37-079 Sensor], Precision Medical
[PM5900, #504877], Puritan-Bennett [see Covidien], Teledyne [R17MED,
#C-43690 (see Max-7 for AX/MX300 replacement), Teleflex Medical [5567,
V-11], Viasys [66030 Sensor, 6400 Vent, 8400 Vent, VIP Vent], VTI
[100580]
|
|
Stock
Number:
ASR116P80 Warranty: 14 Months Replacement For: Devilbiss
[02ANA-101 Sensor], Mercury Medical [10-103-13], MSA [806572, MiniOx
IA], Pacifitech [PT-26]
|
|
Stock
Number:
ASR114P70 Warranty: 24 Months
Replacement For: Covidien (Puritan-Bennett) [4-072214-00, 840, 740, 760 & PB2000 Tester Vents]
|
|
Stock
Number:
ASR114P73 Warranty: 12 Months
Replacement For: Versamed [Versamed Vent] * Note: Oxygen cell
characterized by a particularly long life and extended temperature range (60C)
|
|
Stock
Number:
ASR116P10 Warranty: 12 Months
Replacement For: Analytical Industries [PSR-11-77], Hudson RCI [see Teleflex Medical], Mercury medical [10-103-02], Pacifitech [PT-03], Penlon [MTS], Teledyne [T-7],
Teleflex Medical [5558. V-03]
|
|
Stock
Number:
ASR116P40 Warranty: 12 Months
Replacement For: Analytical Industries [PSR-11-33-1], Hudson RCI [see Teleflex Medical], Mercury Medical [10-103-01], Pacifitech
[PT-02], Teledyne [C1R, #B-39022], Teleflex Medical [5569, V-02, 5525,
5528, 5529, 5550, 5552]
|
|
Stock
Number:
ASR116P60 Warranty: 12 Months
Replacement For: Analytical INdustries [PSR-11-33-1], Hamilton [HM-01, Veolar, Amadeus, Arabella], Hudson RCI [See Teleflex Medical], Mercury Medical [10-103-00], Pacifitech [PT-01], Teledyne [C1R, #A-37016], Teleflex Medical [5568 C1, C-01]
|
|
Stock
Number:
ASR116P06 Warranty: 12 Months
Replacement For: City Technologies [MOX-1], Criticare [Poet IQ 8500, IQ2 8500Q, CAT644 Sensor], EnviteC [OOM-102], Teledyne [R22, #C-44611]
|
|
Stock
Number:
ASR109P07 Warranty: 12 Months
Replacement For: GE (Datex-Ohmeda) [Giraffe]
|
|
Stock
Number:
ASR112P16 Warranty: 12 Months
Replacement For: Teleflex Medical (Hudson RCI) [5800 Monitor, 5801 Analyzer, 5803 Sensor]
|
|
Stock
Number:
ASR125P01-002 Warranty: 24 Months
Replacement For: Maxtec [OM-25A], Mercury Medical [10-103-11], Pacifitech [PT-250], Teledyne [R29]
|
|
Stock
Number:
ASR125P01-002 Warranty: 12 Months
Replacement For: Maxtec [MaxO2+AE, OM-25AE, OM-25ME, MaxBlend, MaxVenturi], Analytical Industries [PSR-11-917-J1], CareFusion (Cardinal, Viasys) [Sentry Blender], Fluke [VT Mobile], mercury Medical [10-103-08], Newport Medical [e360 & e500 Vents], Pacifitech [PT-25A], Teledyne [R29MED/#C-70592], Viasys [Sentry Blender, 66045]
|
|
Stock
Number:
ASR115P85 Warranty: 12 Months
Replacement For: Maxtec [MaxO2+AE, OM-25AE, OM-25ME, MaxBlend, MaxVenturi]
|
|
Stock
Number:
ASR125P02-011 Warranty: 24 Months
Replacement For: Maxtec [MaxO2+A]
|
|